Catalogue - In-Line Heaters

Illustration of Electric Only Line Heater

LHR Series - Electric Only
Ratings from 6 to 36 kW

PDF File

CES Series - Steam and Electric-
20,000 to 200,000 Btu/hr

PDF File

EHL Series - Electric Only
Ratings from 36 to 144 kW

PDF File

PB Series - Steam and Electric-
20,000 to 160,000 Btu/hr

No Drawing Available

General Instructions (PDF)

Download

CCS Series - Steam Only-
20,000 to 200,000 Btu/hr

No Drawing Available

Line Heater Catalogue (PDF)

Download

 Quote / Specification Sheet (DOC File)

DOC File

NEW!
Download a Quote sheet, add your relevant information and email it to us for a fast Quotation
(For Electric Line Heaters only)

 

BACK

LHR Series - Electric Only

Range 6 to 30 kW

List
Number

Rating
kW

Gallons / hr
Litres / hr
Raised 35oC

No. & Rating
of Elements
(Standard)

LHR 01

6

50 / 230

3 @ 2.0 kW

LHR 02

9

80 / 360

6 @ 1.5 kW

LHR 03

12

100 / 455

6 @ 2.0 kW

LHR 04

18

150 / 680

6 @ 3.0 kW

LHR 05

24

200 / 910

12 @ 2.0 kW

LHR 06

30

300 / 1360

12 @ 2.5 kW

LHR 07

36

400 / 1820

12 @ 3.0 kW

General uses include :
Small mains for low output burner systems
Small factory systems
Low cost installations
Pumping & Heating Units
This range is NOT generally suitable for use with Waste / Recycled Oil - ASK if you wish to use this fluid
Special Applications for Water, Chemicals etc, in Stainless Steel

All units have a Watts Rating appropriate to the fluid type used, which for oil is between 4 and 6 W/sq.in. ( 0.6 and 0.9 W/sq.cm.)
Standard Working Pressures up to 30 Bar(g)

The outputs shown are the best values obtainable for the particular heater at the stated temperature rise. Other temperature rises may be calculated on a pro-rata basis, i.e.

600 litres/hr @ 6kW load = 15 C rise, so
300 litres/hr @ 6 kW load = 30 C rise

Formula : kW = litres/hr x temp rise (C) / 1464

Standard Equipment :
Removable Core type Heating Elements
Controlling and Safety Thermostats as appropriate
Thermometer
Relief Valve
Oil Outlet & Oil Return connections to suit
Weathertight terminal cover arrangement
Cable Entries to suit
Mountings to suit application

See Also Control Panels for the above ranges of heaters
(On a separate page)

Extra Items are :
Multiple stage design, extra thermostat, wiring etc.
Delivery UK - usually a nominal charge only.
Other Kilowatt loadings available on request

EHL Series - Electric Only

Range 36 to 144 kW

List
Number

Rating
kW

Gallons / hr
Litres / hr
Raised 35oC

No. & Rating
of Elements
(Standard)

EHL 11

30

300 / 1360

15 @ 2.0 kW

EHL 12

36

400 / 1820

15 @ 2.4 kW

EHL 13

48

500 / 2270

15 @ 3.2 kW

EHL 14

60

600 / 2730

15 @ 4.0 kW

EHL 15

72

700 / 3180

18 @ 4.0 kW

EHL 16

84

800 / 3640

18 @ 4.6 kW

EHL 17

96

900 / 4090

18 @ 5.3 kW

EHL 18

108

1000 / 4550

18 @ 6.0 kW

EHL 19

120

1200 / 5460

24 @ 5.0 kW

EHL 20

144

1400 / 6364

24 @ 6.0 kW

General uses include :
Large ring main systems
Quarry applications with Waste / Recycled oil - MUST BE SPECIFIED AS SUCH
Power Station applications
Pumping & Heating Units
Special Applications for Water, Chemicals etc., in Stainless Steel
Special configurations available

All units have a Watts Rating appropriate to the fluid type used, which for oil is between 4 and 6 W/sq.in. ( 0.6 and 0.9 W/sq.cm.)
Standard Working Pressures up to 30 Bar(g)

Ratings based on Oil Inlet Temperature of 55 C and an Oil Outlet Temperature of 90 C

Standard Equipment :
Removable Core type Heating Elements
Controlling and Safety Thermostats as appropriate
Thermometer
Relief Valve
Oil Outlet & Oil Return connections to suit
Weathertight terminal cover arrangement
Cable Entries to suit
Mountings to suit application

See Also Control Panels for the above ranges of heaters
(On a separate page)

Extra Items :
Multiple stage design, extra thermostat, wiring etc.
Delivery UK - usually a nominal charge only.
Other Kilowatt loadings available on request

Back to Top

CES Series - Steam / Electric

Range 20,000 to 200,000 Btu/hr

List
Number

Rating
kW

Gallons / hr
Litres / hr
Raised 35oC

No. & Rating
of Elements
(Standard)

Steam Heating Surface Area
(Typical)

CES 01

3

50 / 230

1 @ 3.0 kW

10 ft2 / 0.9m2

CES 02

6

100 / 4550

3 @ 1.0 kW

20 ft2/ 1.9m2

CES 03

6

150 / 680

3 @ 2.0 kW

30 ft2 / 2.8m2

CES 04

9

200 / 910

3 @ 3.0 kW

40 ft2 / 3.7m2

CES 05

12

250 / 1140

6 @ 2.0 kW

50 ft2 / 4.6m2

CES 06

15

300 / 1360

6 @ 2.5 kW

60 ft2 / 5.6m2

CES 07

15

350 / 1600

6 @ 2.5 kW

70 ft2 / 6.5m2

CES 08

15

400 / 1820

6 @ 2.5 kW

80 ft2 / 7.4m2

CES 09

18

450 / 2050

9 @ 2.0 kW

90 ft2 / 8.4m2

CES 10

18

500 / 2300

9 @ 2.0 kW

100 ft2 / 9.3m2

General uses include :
Small mains for low output burner systems
Pumping & Heating Units
Small factory systems
Low cost installations
This range is NOT suitable for use with Waste / Recycled Oil
Special Applications for Water, Chemicals etc, in Stainless Steel

Standard Equipment :
Removable Core type Heating Elements
Controlling and Safety Thermostats as appropriate
Thermometer
Relief Valve
Oil Inlet & Oil Outlet connections to suit
Weathertight Terminal Cover arrangement
Cable entries to suit
Mountings available in a variety of designs - i.e. Vertical, Wall mounted

PB Series - Steam / Electric

List
Number

Rating
kW (50%)

Gallons / hr
Litres / hr
Raised 78oC

No. & Rating
of Elements
(Standard)

Steam Heating Surface Area
(Typical)

PB 01

6

27 / 120

3 @ 2.0 kW

20 ft2 / 1.9m2

PB 02

12

54 / 240

3 @ 4.0 kW

20 ft2 / 1.9m2

PB 03

15

66 / 300

3 @ 5.0 kW

20 ft2 / 1.9m2

PB 04

18

80 / 360

3 @ 6.0 kW

25 ft2 / 2.3m2

PB 05

24

100 / 455

9 @ 2.6 kW

40 ft2 / 3.8m2

PB 06

30

130 / 590

9 @ 3.3 kW

70 ft2 / 3.8m2

PB 07

36

160 / 730

9 @ 4.0 kW

80 ft2 / 6.5m2

PB 08

48

210 / 950

9 @ 5.3 kW

80 ft2 / 7.4m2

General uses include :
Package Boiler units
Pumping & Heating Units
Special Applications for Water, Chemicals etc., in Stainless Steel
Special configurations available

Standard Equipment :
Removable Core type Heating Elements
Controlling and Safety Thermostats as appropriate
Thermometer
Relief Valve
Oil Intlet & Oil Outlet connections to suit
Weathertight Terminal Cover arrangement
Cable entries to suit
Mountings available in a variety of designs - i.e. Vertical, Wall mounted

Extra Items :
Spirax Sarco Steam Regulator & Control Valve
Steam Trap set, sight glasses etc.
Multiple stage design, extra thermostat, wiring etc.
Delivery UK - usually a nominal charge only.
Other Kilowatt loadings available on request
Other Steam Surface Areas available on request

 


Back to Top

CCS Series - Steam Only

Output Range 20,000 - 200,000 Btu/hr

List
Number

Gallons / hr
Litres / hr
Raised 35oC

Steam Heating Surface Area
(Typical)

CCS 01

50 / 230

10 ft2 / 0.9m2

CCS 02

100 / 455

20 ft2 / 1.9m2

CCS 03

66 / 300

30 ft2 / 2.8m2

CCS 04

80 / 360

40 ft2 / 3.8m2

CCS 05

250 / 1140

50 ft2 / 4.6m2

CCS 06

300 / 1360

60 ft2 / 5.6m2

CCS 07

350 / 1600

70 ft2 / 6.5m2

CCS 08

400 / 1820

80 ft2 / 7.4m2

CCS 09

450 / 2050

90 ft2 / 8.4m2

CCS 10

500 / 2300

100 ft2 / 9.3m2

Standard W.P. up to 30 bar with Steam Pressure 14 bar maximum.
All units sized using 3.4 bar(g) steam
Oil Inlet Temperature : 55oC / Oil Outlet Temperature : 90oC

General uses include :
Package Boiler units
Pumping & Heating Units
Special Applications for Water, Chemicals etc., in Stainless Steel
Special configurations available

Standard Equipment :
Removable Core type Heating Elements
Controlling and Safety Thermostats as appropriate
Thermometer
Relief Valve
Oil Intlet & Oil Outlet connections to suit
Weathertight Terminal Cover arrangement
Cable entries to suit
Mountings available in a variety of designs - i.e. Vertical, Wall mounted

Extra Items :
Spirax Sarco Steam Regulator & Control Valve
Steam Trap set, sight glasses etc.
Multiple stage design, extra thermostat, wiring etc.
Delivery UK - usually a nominal charge only.
Other Kilowatt loadings available on request
Other Steam Surface Areas available on request

Top