OHR Series - Electric Only

Range 6 to 30 kW

List
Number

Rating
kW

Litres / hr
Raised 15oC

No. & Rating
of Elements

Length &
Shell O.D.

Flange Size

OHR 01

6

600

3 @ 2.0 kW

1100 / 250

No.6

OHR 02

9

900

6 @ 1.5 kW

1100 / 250

No.6

OHR 03

12

1200

6 @ 2.0 kW

1100 / 270

No.7

OHR 04

18

1800

6 @ 3.0 kW

1100 / 270

No.7

OHR 05

24

2400

12 @ 2.0 kW

1100 / 320

No.9

OHR 06

30

3000

12 @ 2.5 kW

1100 / 320

No.9

The heaters shown are for fitting to a storage tank where a suitable flanged connection exists. A similar unit, without a flange, can be provided to Weld In to the tank, if desired.
General uses include :
Small storage tanks for oil (or water to special Order)
Low cost installations

All units have a Watts Rating appropriate to the fluid type used , which is between 6 and 8 W/sq.in. ( 0.9 and 1.2 W/sq.cm.) for oil.

Ratings based on Oil StorageTtemperature of 40 C and an Oil Outlet Temperature of 55 C

Standard Equipment :
Removable Core type Heating Element
Controlling and Safety Thermostats as appropriate
Thermometer
Oil Outlet & Oil Return connections to suit
Weathertight Terminal Cover arrangement
Cable entries to suit


Back to Top

OEH Series - Electric Only

Range 36 to 144 kW

List
Number

Rating
kW

Litres / hr
Raised 15oC

No. & Rating
of Elements

Length &
Shell O.D.

OEH 12

36

3600

15 @ 2.4 kW

1500 / 356

OEH 13

48

4800

15 @ 3.2 kW

1500 / 356

OEH 14

60

6000

15 @ 4.0 kW

2000 / 356

OEH 15

72

7300

18 @ 4.0 kW

2000 / 356

OEH 16

84

8500

18 @ 4.6 kW

2000 / 406

OEH 17

96

9700

18 @ 5.3 kW

2500 / 406

OEH 18

108

10900

18 @ 6.0 kW

2500 / 406

OEH 19

120

12100

24 @ 5.0 kW

2500 / 460

OEH 20

144

14600

24 @ 6.0 kW

2500 / 460

General uses include :
Large storage tanks for oil

Ratings based on Oil StorageTemperature of 40 C and an Oil Outlet Temperature of 55 C

Standard Equipment :
Removable Core type Heating Element
Controlling and Safety Thermostats as appropriate
Thermometer
Oil Outlet & Oil Return connections to suit
Weathertight terminal cover arrangement
Cable Entries to suit

See Also Control Panels for the above ranges of heaters (See separate page)

Extra Items :
Multiple stage design, extra thermostat, wiring etc.
Delivery UK - usually a nominal charge only.
Change of Flange specification.
Other Kilowatt Ratings available on request


Back to Top

CSO Series - Steam / Electric

Range 20,000 Btu/hr to 200,000 Btu/hr

List
Number

Rating kW
(30% approx)

Litres / hr
Raised 15oC

No. & Rating
of Elements

Steam Heating Surface Area

CSO 01

3

800

1 @ 3.0 kW

10 ft2 / 0.9m2

CSO 02

6

1600

3 @ 2.0 kW

20 ft2 / 1.9m2

CSO 03

6

2500

3 @ 2.0 kW

30 ft2 / 2.8m2

CSO 04

9

3300

3 @ 3.0 kW

40 ft2 / 3.7m2

CSO 05

12

4200

6 @ 2.0 kW

50 ft2 / 4.6m2

CSO 06

15

5000

6 @ 2.5 kW

60 ft2 / 5.6m2

CSO 07

18

5900

6 @ 3.0 kW

70 ft2 / 6.5m2

CSO 08

18

6700

6 @ 3.0 kW

80 ft2 / 7.4m2

CSO 09

24

7600

6 @ 4.0 kW

90 ft2 / 8.4m2

CSO 10

24

8500

6 @ 4.0 kW

100 ft2 / 9.3m2

The heaters shown are for fitting to a storage tank where a suitable connection exists. A similar unit, without a flange, can be provided to Weld In to the tank, if desired.
General uses include :
Small storage tanks for oil (or water to special Order)
Low cost installations

All units have a Watts Rating appropriate to the fluid type used , which is between 5 and 8 W/sq.in. ( 0.77 and 1.2 W/sq.cm.) for oil.
All units sized using 3.4 bar(g) steam
Heaters can use a Steam Pressure of 14 bar(g) Maximum

Ratings based on Oil StorageTemperature of 40 C and an Oil Outlet Temperature of 55 C

Standard Equipment :
Removable Core type Heating Elements
Controlling and Safety Thermostats as appropriate
Thermometer
Oil Outlet & Oil Return connections to suit
Weathertight Terminal Cover arrangement
Cable entries to suit

The outputs shown are the best values obtainable for the particular heater at the stated temperature rise. Other temperature rises may be calculated on a pro-rata basis, i.e.

600 litres/hr @ 6kW load = 15 C rise, so
300 litres/hr @ 6 kW load = 30 C rise

Formula : kW = litres/hr x temp rise (C) / 1464

Extra Items are :
Spirax Sarco Steam Regulator & Control Valve
Steam Trap set, sight glasses etc.
Multiple stage design, extra thermostat, wiring etc.
Change of flange specification to non-standard
Delivery UK - usually a nominal charge only.
Other Kilowatt Ratings available on request
Other Steam Surface Areas available on request

Back to Top

CCO Series - Steam Only

Range 25,000 Btu/hr to 270,000 Btu/hr

List Number

Output in BTU's / hr

Litres / hr
Raised 15oC

Steam Heating
Surface Area

CCO 01

25,000

800

10 ft2 / 0.9m2

CCO 02

50,000

1600

20 ft2 / 1.9m2

CCO 03

80,000

2500

30 ft2 / 2.8m2

CCO 04

100,000

3300

40 ft2 / 3.7m2

CCO 05

130,000

4200

50 ft2 / 4.6m2

CCO 06

150,000

5000

60 ft2 / 5.6m2

CCO 07

185,000

5900

70 ft2 / 6.5m2

CCO 08

210,000

6700

80 ft2 / 7.4m2

CCO 09

240,000

7600

90 ft2 / 8.4m2

CCO 10

270,000

8600

100 ft2 / 9.3m2

General uses include :
Large storage tanks for oil where temperature is controlled in a sector fashion.

Ratings based on Oil StorageTemperature of 40 C and an Oil Outlet Temperature of 55 C

Standard Equipment :
Thermometer
Oil Outlet & Oil Return connections to suit

See Also Control Panels for the above ranges of heaters

Extra Items :
Change of Flange specification to non-standard
Delivery UK - usually a nominal charge only.
Other Kilowatt Ratings available on request
Other Steam Surface Areas available on request

Back to Top